Leaders in cost effective compressed air solutions.
CPX/HT Series
CPX Series Refrigerated Dryers
THE CPX REFRIGERATED AIR DRYERS FOR ALL APPLICATIONS Sized to handle 12 to 2472 CFM, the CPX dryers fit any application. Extremely quiet and reliable, CPX dryers deliver dry air with minimal pressure drop.
FEATURES:
Eliminates Water, Oil and Dirt from Air Systems
Prevents Damage to Tools and Cylinders, Adding to their Longevity
Fewer Finished Product Defects
Prevents “Fisheye” Paint Splotches
Reduces Operational Downtime
Increases Profitability and Productivity
Eliminates Air Line Purging
Compact Design for Small Footprint
Quality Components for Efficient Cooling
Internal Layout and Enclosure Allow for Quite Operation
Model
cfm@100 psig
Max Pressure psig
Electrics V/Hz/Ph
L in.
W in.
H in.
Weight lbs.
Refrigerant
Noise dBa
CPX 10
12
240
230/60/1
350
497
450
42
R-134a
50
CPX 20
21
240
230/60/1
350
497
450
42
R-134a
50
CPX 30
30
240
230/60/1
350
497
450
44
R-134a
47
CPX 40
43
240
230/60/1
350
497
450
55
R-134a
53
CPX 60
65
240
230/60/1
350
497
450
59
R-134a
53
CPX 80
83
240
230/60/1
370
500
764
97
R-404a
57
CPX 100
106
195
230/60/1
370
500
764
97
R-404a
57
CPX 125
127
195
230/60/1
460
560
789
117
R-404a
58
CPX 150
145
195
230/60/1
460
560
789
132
R-404a
58
CPX 180
184
195
230/60/1
460
560
789
145
R-404a
58
CPX 225
225
195
230/60/1
580
590
899
176
R-404a
59
CPX 270
270
195
230/60/1
580
590
899
176
R-404a
59
CPX 350
300
195
460/60/3
735
898
962
282
R-404a
60
CPX 425
400
195
460/60/3
735
898
962
321
R-404a
67
CPX 530
500
195
460/60/3
735
898
962
348
R-404a
67
CPX 700
600
195
460/60/3
735
898
962
363
R-404a
68
CPX 850
848
195
460/60/3
1020
1082
1535
737
R-404a
70
CPX 1000
1060
195
460/60/3
1020
1082
1535
759
R-404a
71
CPX 1200
1237
195
460/60/3
1020
1082
1535
777
R-404a
71
CPX 1700
1766
195
460/60/3
1020
2099
1535
880
R-404a
74
CPX 2500
2472
195
460/60/3
1020
2099
1535
891
R-404a
74
CPXHT High Temp Dryer
A perfect complement to the RCP With a maximum inlet temperature of 180°F, no aftercooler is required. Included filtration eliminates dirt and oil giving you clean, dry compressed air. The CPXHT dryers are easy to install and have a compact design. Supplied with 115 Volt power means no special wiring is required and the space saving design incorporates an air cooled aftercooler, refrigerated air dryer, moisture separator, electronic water drain and coalescing filter.
FEATURES:
Eliminates Water, Oil and Dirt from Air Systems
Prevents Damage to Tools and Cylinders, Adding to their Longevity
Fewer Finished Product Defects
Prevents “Fisheye” Paint Splotches
Reduces Operational Downtime
Increases Profitability and Productivity
Eliminates Air Line Purging
Compact Design for Small Footprint
Quality Components for Efficient Cooling
Internal Layout and Enclosure Allow for Quite Operation
Model
50°F PDP cfm@100 psig
Use with
Electrics
Ref hp
Heat Exchanger
Max psig
Refrigerant
L in.
W in.
H in.
Lbs.
Cnxn (NPT)
CPXHT-25
25
5 hp
115/1/60
1/4
Copper
175
R-134a
17.5
19
18
85
1/2”
CPXHT-50
50
10 hp
115/1/60
1/4
Copper
175
R-22
28
20
30
128
1/2”
CPXHT-75
75
15 hp
115/1/60
1/2
SS/Copper
175
R-134a
28
18
40
183
1”
CPXHT-100
100
20 hp
115/1/60
3/4
SS/Copper
175
R-134a
28
18
40
194
1”
CPXHT-125
125
25 hp
115/1/60
3/4
SS/Copper
175
R-134a
28
18
40
200
1”
Maximum Ambient 100°F Minimum Ambient 40°F Dew Point Temp 50°F +/- 2°F Maximum Inlet Temp 180°F